However, to know more about the exact causes and solutions of all the above troubles, keep reading this articles each point. Performance & security by Cloudflare. After cleaning, reassemble the pilot assembly. Then, proceed with relighting the pilot per the steps outlined above. If you are having a problem with your igniter lighting your water heater, then chances are it is not a problem that resetting it will fix. If your Honeywell water heater has no status light, our guide will prove quite effective in resolving this problem. Your igniter should light the gas directly if it is a hot surface ignition. But before moving to the detailing part, let us walk you through a quick table highlighting all the possible reasons with quick solutions:Probable ReasonsPossible SolutionsThe pilot is not lighting> Clean out the pilot tube.> Relight the pilot following proper instructions.No spark at the igniter> Verify the whiter igniter is firmly inserted into the white or orange connector.> Clean the corroded igniter connection with sandpaper. The furnace gas valve for this type of furnace is identifiable with its solenoid designations: MV (main valve), PV (pilot valve), and PV/MV (common). Lets look at some of the most common problems, so that we may find the solutions. Remove the two connectors of red and white wires from the gas control valve. > Replace the bad outer door, & defective gas control valve/ thermostat. Once you remove the manifold door, take out the burner assembly from the burner chamber. At the same time as youre holding down the pilot switch, press on the piezo igniter. Turn the thermostat to its lowest possible setting. Attach the red positive lead to the red thermopile wire. There are several actions that could trigger this block including submitting a certain word or phrase, a SQL command or malformed data. Pilot lights, but the main burner doesn't come on. If the heater pilot light keeps going out, be sure there isa faulty, misaligned, dirty, or damaged thermocouple responsible for this. If the igniter fails, the burner will not light. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. It will ensure a fluent gas flow. If your pilot flame lights but keeps going out, its vent is most likely dirty and/or clogged. Save my name, email, and website in this browser for the next time I comment. Flashing the status light on your newly installed heater may require 2-3 lighting attempts. The error codes flashes 0, 1, 2, 4, 5, 7, & 8 times. Interruption In The Gas Supply 4. If the ignition fails, the water will not get hot enough. Induced draft water heaters use an intermittent pilot or hot surface ignition instead of a standing pilot light. The simple resolving ways are: The Honeywell water heater knob stuck is another problem you may experience while using this heater. Cloudflare Ray ID: 7a29f4b64efb28ee When all is done, the status should start blinking. Note: You can also read how to fix Honeywell hot water heater status light blinking 7 times. Locate the hot surface igniter and look for a spark or glow there. Eric,your tutorial was very helpful, Im from El Paso as well. If no spark is coming, check the igniter connection for any corrosion. Due to inadequate gas, your heater fails to ignite and heat the water. Either the pilot light is going out, or the pilot light is failing to start. Step #4: Take a look at the viewport to see if the pilot light comes on. If you are getting too much voltage, (over 125 VAC) it can cause your igniter to fail. Using oil will ruin the valve and damage the seal. Sometimes it may be an easy fix, such as a loose wire, other times, it may be something more advanced, such as a bad thermocouple. Most Honeywell water heaters with electric gas valves need just 12 volts for the valve to work. What are the symptoms of a broken water heater? If your hot water heater suddenly stops working, chances are a bad thermocouple has shut off the gas to the pilot light. If the igniter wires come loose from their connector, the controller will receive no signal for ignition. Dont miss to check the gas valve. If you find any wire or plug broken you can call the electrician to fix it. Honeywell Hot Water Heater No Status Light [7 Easy Solutions] 1. There are several reasons behind the no blink on the Honeywell Status light. She grew up surrounded by constant home improvement projects and owes most of what she knows to helping her dad renovate her childhood home. 1 Additionally, these devices are fueled with flammable natural gas. Replace the defective pipe. Blocked vents or insufficient air supply. How do you light a hot water heater with an igniter Honeywell? Check all wiring connections. Check for any obvious dirt or debris that could be clogging the pilot and clean accordingly. Your water heater wont work properly if the igniter wont spark. Problem with the thermocouple: However, the most standard procedure for lighting a gas water heater pilot light is as follows: Again, this process may vary slightly based on the make and model of your water heater. Lastly, make sure you keep the white connector far from the metal pilot tube, manifold tube, and manifold door. Hold down the pilot button and keep depressing the igniter button until the pilot light comes on. Should I Turn Off An Electric Water Heater If The Water Is Off? Just set the gas control knob to Off position for 5 to 7 minutes to let the gas clear out. FV sensors also go into lockout mode when the sensor becomes damaged or defective. Now inspect the vents of the heater. Tighten all the wiring connections. Usually, next to your heaters pilot light, you will find the thermocouple. It may be rust, oil, grime, dirt, or excess air in the system. When this component gets damaged by corrosion or bent, it wont function anymore. If you cant find the problem, or the problem is too advanced, dont hesitate to call a licensed service professional. I'm a writer that is passionate about home improvements, remodeling, and renovating. Step #2: After that time, set the control knob to the pilot position. When the water pressure within the tank of a water heater reaches a steady stream, the ignition process is signaled to continue by means of a faulty pressure switch that has closed some sort of circuit. Take a brush-attached vacuum cleaner to clean out the clogged dust or lint. Also, it should not touch the metal pilot tube and manifold tube. Quick Solutions For Honeywell Water Heater Status Light Not Blinking, Honeywell Hot Water Heater No Status Light [7 Easy Solutions], 4. The below table will provide you with a clear idea: i. COPYRIGHT 2023. Get a new igniter, which looks like the below screenshot. Easy things, you will be able to work on yourself. Thank for your feedback. He has a good standing reputation for superior skills in heating, air conditioning, hot water tanks, and indoor air quality systems. To fix your hot water heater issue, follow our solution guide in the hot water heater pilot wont light section of the article. Wait for 10 minutes. Extracted igniter wires that come out of the white connector are the first I blame most. Check out the complete heater elements and look for any leaks. Each of them indicates different problems. To solve this problem, use a wire brush to remove any dirt or corrosion from the inside circuit at the top of the water heater tank and try lighting it again. If the Honeywell water heater light is not blinking, it may be due to a faulty light switch. If you do not have leak detector use water and dish soap mixed at about 75% 25% respectively. Clean the pilot tube using a sharp object to remove the blockages. Honeywell water heater high temperature shut downyour heater and the unit stopped working. Pilot lights can take a few tries to get lit. ), blinking light on a different number of times, How to fix Honeywell water heater status light blinking 7 times, How to fix Honeywell water heater status light blinking 3 times, water heater shuts down due to a high temperature, Honeywell water heater light is not blinking, Rheem Tankless Water Heater Maintenance [Why+ How To Do], Rheem Tankless Water Heater Code 61 [Why+ How To Fix], Rheem Tankless Water Heater Code 14 [Why+ How To Fix], Rheem Tankless Water Heater Code 99 [Why+ How To Fix], Rheem Tankless Water Heater Code 76 [Why+ How To Fix]. Higher chances are base-ring filters or the flame arrestor is blocked by carbon dust and debris, creating combustion issues in the heater. This is a more advanced problem. The no status light issue on your Honeywell water heater gas control valve should be solved. link to What Kind Of Paint For Garage Walls? Typically, an igniter on a water heater lasts around 7 to 15 years. We store towels, medicine, toiletry supplies, first-aid gear, massage devices, facial steamers, spare Painting your garage is a great way to improve the look of the space and make the walls easier to clean. When the gas is burned from the primary heat exchanger, the second exchanger draws heat from the exhaust. In most cases, the status light doesnt blink due to inadequate air supply. In the following table we will explain what different times LED flashes mean, their causes, and solutions: Turn on your heaters Pilot, and for 10 seconds, switch the Pilot dial to Very Hot. Then for 10 seconds, switch the dial to Hot. And again, for 10 seconds, change it to Pilot.. Depending on the water heater you have, it may use an igniter to ignite the gas. Ensure the drain valve is unclogged and working fluently. Manage Settings The stuck knob may cause your heater to overheat also. You will need to use your multimeter to test it. Use a Multimeter to check the voltage drop across the valve. Then properly clean it, Ensure your heater is getting an adequate gas supply, Air in the gas line or insufficient air supply, Replace the malfunctioning thermopile, bad gas control valve and its lousy wiring, tripping thermal switch, & stuck gas control knob, Tighten the gas control valves wiring connection, Clean the gas lines air and ensure the sufficient air supply. Usually, when your heaters pilot light stops lighting or goes out, your water heater will stop heating. If the power supply to the water heater is not working, you may need to replace the fuse or circuit breaker. To do so, set the control knob to the Off position and wait for 5 to 10 minutes. The main reason for the Honeywell water heater not becoming hot enough is the malfunctioning of the thermostat. After going through our ultimate guide, already you know what are the common Honeywell water heater problems, their reason, and solutions. Manage Settings Make a proper adjustment to the thermostat. Heater Knob Stuck 10. Your hot water heater may not be sparking due to a defective igniter, electrode or thermocouple. Verify the water pipes are properly insulated and ventilated. Some water heaters use an ignition source to ignite the gas. Step 3: Check for Spark. How To Stop Wind From Blowing Out Pilot Light (On A Water Heater). Another serious problem you can often experience is yourHoneywell water heater wont ignite. This means, if the power is out, you will not be able to light the hot water heater. How do I reset my Honeywell water heater? Burner Will Not Ignite 8. Inspect the igniter, for any bad wiring, and if you find any, you may need to resolder the wire or have a professional reattach them for you. Whether your water heater is running or not, in some water heaters, the pilot light is always burning while using a minute amount of gas. These can include problems with the water heaters storage tank or coils, which would require expensive repairs or replacement. To do this, turn the water temperature dial to Low and the On/Off/Pilot knob to Pilot. Then, check and replace the bad gas control valve. What if the Honeywell water heater light not blinking? Continuously thermopile generates electric power while the gas valve/temperature knob is turned off. For instance: Follow the below instruction to resolve the above igniter issues: First up, you have to check the wiring connection of the igniter.